Power supply
Patented output filter with ripple cancellation networkLow Inrush Limiting reduces AC inrush current, removing the need for expensive power sequencers
Detachable AC mains cable with IEC C19/22.2 (16A for EU, 20 A for USA) socket
Protections
Fully protected circuit design with:
Ac protection: shut down power supply when AC mains voltage is outside operating rangeClip limiter: prevents severely clipped waveforms from reaching loudspeakers, while still maintaining full peak power output
DC protection: protects against infrasonic signal at the outputs
VHF protections: protects the loudspeakers against non audible, strong, non musical high frequency signals
Short circuit protection: protects the amplifier from short circuit or other stressful events for the output circuits with automatic protection reset
Long term limiter: protects the loudspeaker against steady long term RMS (non audio) signals, by reducing maximum output
Thermal protection: output stages operating temperature up to 80 °C (176 °F)
Temperature controlled continuous variable speed fan, front to back airflow
Temperature forecast with LCD traced historical behavior
General
Fixed frequency switch-mode output stage for high grade sound accuracyCompact size – all models only 1 RU for reduced rack cost and space
Light weight – for easier racking and shipping: 7 kg (15.4 lbs)
Standard Phoenix connectors: analog audio outputs, aux supply, alarms and GPIO
Remotely switchable double input (main and aux) per channel
Settings
Built-in defeatable clip limiters for each channelDigital gain-attenuator control
Defeatable gate selection for each channel
User selectable gain/sensitivity
User selectable maximum output power for each channel
User selectable maximum mains current draw
Lockable set-up by user selectable access key code
Built in remote control via the RS-485 interface provides full diagnostic, operational setting and system monitoring
Digital Signal Processing
TI C6000 DSP platformAD/DA converter: dual 24bit @ 48 kHz Tandem® architecture
Input/output independent equalizers per channel providing PEQ, raised cosine, shelving IIR filters as well as custom output FIR filters
Delay up to 100 ms for time alignment
Active DampingControl™ for cable compensation
Peak, RMS voltage, RMS current, TruePower™ limiters
Remote Control and Monitoring
Via Software:
Control and diagnostics monitoring via ArmoniaPlusDedicated WebApp
Via Hardware:
Attenuation (from 0dB to 26dB)High-pass filters (35Hz, 70Hz)
Lo-Z/Hi-Z/70V/100V output selection
Adjustable gain (from 26dB to 35 dB)